Testing

How water hardness is measured

Use one consistent unit before comparing your water report, test result and equipment specification.

Written by Limescale Logic editorial deskUpdated 9 October 2026Practical guide
In brief

Use one consistent unit before comparing your water report, test result and equipment specification.

The reference unit

UK consumer guidance commonly expresses total hardness as mg/L of calcium carbonate, written mg/L CaCO3. Parts per million is numerically equivalent to mg/L for this purpose in ordinary water comparisons.

Other units

Reports and equipment may use degrees Clark, French degrees or German degrees. Convert both values to mg/L CaCO3 before deciding whether a system is correctly sized.

Supplier report or home test?

A supplier report represents the relevant supply zone and is the sound first reference for mains water. Drop tests can be useful for commissioning or checking treated water when performed correctly. Test strips are convenient but usually provide a broader range.

Avoid false precision

Water sources and blends can change. Treat a single result as a decision input, not an immutable property of the address. Ask the supplier about unusual variation and follow the test manufacturer's instructions.

A worked conversion

Suppose a report gives 250 mg/L as calcium carbonate. Divide by 10 to get 25 French degrees, by 17.848 to get about 14.0 German degrees, or by 14.254 to get about 17.5 degrees Clark. These are illustrative calculations using the same quantity, not four separate tests.

Convert to mg/L as calcium carbonate
Reported unitMultiply byExample
French degrees1025 becomes 250 mg/L
German degrees17.84814 becomes about 250 mg/L
Degrees Clark14.25417.5 becomes about 249 mg/L

“As calcium carbonate” is part of the unit. A report's calcium concentration is not automatically its total hardness expressed as calcium carbonate. If a value is labelled ambiguously, ask the supplier rather than treating every mg/L number as hardness.

Choose a test for the question

For appliance settings, the manufacturer may specify a strip or titration method. For checking an installed softener, compare untreated and treated outlets using the method specified by the supplier or installer. Follow the sampling and reading instructions consistently.

Keep the original reading and any rounded converted result separate. Rounding is useful for explaining a result; equipment settings may require the original value, range or the next setting band in a model-specific table.

Measurements this cannot substitute for

  • A conductivity or TDS reading does not identify every dissolved substance.
  • A hardness test does not measure the sodium added by a particular softener.
  • Neither test establishes that lead, bacteria or another specific hazard is absent.

Ask for a test designed for the actual concern. For a suspected drinking-water issue, contact the supplier and follow its sampling advice. Use the converter for arithmetic and the lead guide for the separate pipework question.